They have holes for nails and are screwed to fasten them in place securely. H2.5A 18-Gauge ZMAX Galvanized Hurricane Tie, H1 18-Gauge ZMAX Galvanized Hurricane Tie, HDU 8-11/16 in. Slide the bolts through the holes, put a washer and nut on the threaded end and tighten each nut with a wrench . The 2x8 DNR Joist Notch Repair Kit (Patent Pending) is a structural steel plate designed to restore the strength of Floor Joists that have been compromised due to over cut notches either at the top or bottom of the Joist. The technique is especially useful in roof spaces where the collars are necessarily high for headroom. Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. 1. For example, a wood 2x4 (actually 1.5 x 3.5) has a modulus of around 12.5 and a area moment of around 5.36 inches cubed. The straps extended the entire length of the 16-foot joists, which were supported so that there was 14 feet of span. It's probably too much to ask but if possible it would be good to jack up each beam prior to sistering on a new joist. After running the bolt or rod from the inside out through the ledger, position the deck-joist hardware and screw it in place. Costs for sill plate repairs are between $100-$120 per linear foot. It should be placed at eight-foot intervals between any floor joists 2x10 or longer. Now in our 20th year, we continue to expand to provide the most comprehensive product offering to serve infrastructure, commercial, industrial and residential construction markets. Just kidding, it's all signed off now!". The cut/notch happens to be right smack in the middle of the joist span. The joists are about 15 feet long, and each end sits on a structural masonry exterior load bearing wall (it's a narrow 19th century stone twin). Some orders that are placed early in the day may ship that day while others may not. Click Here for the product design report provided by Nolan Engineering, PLLC. It would also induce/force one to use a NON-slip fastening method. For 9 1/2" LP I-Joists with 1 1/2 " flange width and height. Floor Joist Repair Cost for a 500-Square-Foot Room. The DP34 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. Maximum gap between wood members is 4 1/2". "The steel straps were 1.5-inch by 1/8-inch, and were nailed to the joists with 16p nails 6-inches on center.". They are not generally required at the ends of . 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Same day shipping on orders placed Mon-Fri before 3pm, CALL FOR QUANTITY DISCOUNTS - 540-589-9669, Feel free to call, text, or email 24/7 customer service if you have questions. The CTS218 is designed to repair wood members such as top plates, studs and trusses, and it handles both tension and compression loads. Vinyl window grille insert (bar) missing - does it matter. The concrete repair, protection and strengthening solutions developed by Simpson Strong-Tie are the result of over 40 years of laboratory development, field study and collaboration with professional contractors. The DP30 provides the solution with heavy duty steel and structual fasteners that more than make up for the lost support. Press the space key then arrow keys to make a selection. Features EASY: Includes a built-in nail for easy and quick install.FAST: Only requires Continue Reading How to repair notched/damaged floor joists without sisterring. About 6 inches from the end of the joist, drill a 3/8 inch hole through both joists. Your input is very much appreciated. Adding metal to the height (side) of the joist creates a quasi flitch beam, the problem that occurs is preventing buckling of the metal. 27. The Joist Repair Strap is designed to repair notched, drilled or damaged floor joists without needing to remove any plumbing/wiring which may go through the joist. Simpson Strong-Tie Adjustable Height Joist Hanger Strap 75mm (W) is an industry standard timber hanger for solid joists made of mild steel that is galvanized to provide durable support with ease of installation. Call us at 540-589-9669. The DP24 works for notches up to 6" wide. Bearing End Replacement Use For use to replace rotted ends or as splicing plates to add a new length of timber Supplied as pairs of galvanized steel plates, pre-drilled, to be fixed with Coach Screws (included). This would *pre-stress* the steel, such that it was carrying a significant % of the dead load, right from the go. respondent "brickeyee" provided considerable information on the approach of adding steel strapping to the underneath of the joist. Then use pry bars and your reciprocating saw to pry and cut the floor joist away from the subfloor. The CTS218 is designed to repair wood members such as top plates, studs and trusses, and it handles both tension and compression loads. They use them in shipping. You take a piece of lumber or plywood of appropriate size and affix it permanently to a joist at the precise site of concern. I would like to see these guys try and make a flitch beam. This product is manufactured from pre-galvanised mild steel classified as Euro class A1 in accordance with EN 13501-1, making it resistant to corrosive chemicals and physical impacts. http://www.homebuildingandrepairs.com/repairs/framing/index.html Click on this link for more information about home repairs. The Joist Repair Kit is great for both homeowners, contractors, and DIYers as it includes everything needed to install. admin@nolan-engineering.com, Designed by Elegant Themes | Powered by WordPress. The straps extended the entire length of the 16-foot joists, which were supported so that there was 14 feet of span. Now you can build roads that are stronger and more economical. Press the space key then arrow keys to make a selection. We strap the ceilings after all ceiling and bearing-wall framing is finished. A while back, I considered completing a task that had been on my to-do list for ages - fixing my bouncy living room floor. This strengthens the joint and triangulates the roof. TJI joists with top flange notches. If you want to use nails they should probably be power driven to produce a very tight hole fit. That isn't my goal, but some aspects of the steel strapping results caught my attention. Copyright 2022 Simpson Strong-Tie Company, Inc. A catalog including new product information as well as any applicable specification and installation instructions for wood-to-wood and wood-to-concrete structural connectors. By clicking "I AGREE" below, you are giving your consent for us to set cookies. As the pressure increased, one would expect the slop to be taken up and the slope of the curve to become sharper. Conectores para la construccin con madera 20212023. Scabbing. We use cookies on this site to enhance your user experience. B. The CTS218 is designed to repair wood members such as top plates, studs and trusses and is our first strap that handles both tension and compression loads. El catlogo incluye informacin sobre nuevos productos, as como especificaciones e instrucciones de instalacin aplicables para conectores estructurales de madera a madera y de madera a concreto. The Joist Repair Strap is designed to repair notched, drilled or damaged floor joists without needing to remove any plumbing/wiring which may go through the joist. One-sided installations install one or two CTS straps on the same side of the member. Our product provides an affordable, alternative solution to sistering the joist in order to restore the integrity of the joist and promote safety. The fastening system works here because the fasteners are put in a tensile load, and very little at that since the steel does not buckle. Allowable loads have been increased for wind or earthquake loading with no further increase allowed. Nailing two 2x4s together will work to span about three joists, unless the sag is under a weight-bearing wall. The DP24 will repair a notch up to 6" wide. Be careful not to break the tensile strap though that can get hairy. "Those joist reinforcers worked fantastic! You can scab one or both sides of a joist, based on the reinforcement requirement. Jacking them up too fast may cause cracks in the walls and floors overhead. If the holes are large enough to drive nails it is unlikely you will get much benefit since the joist can still move until the hole tolerance is removed from the movement. Joist End Repair Plates - BM6, BM9 and BM17 (in two depths) 1. a day until they're level. I was enthused about this approach for a problem with my own house until I came across a paper by the Corps of Engineers titled "Evaluation of Expedient Techniques for Strengthening Floor Joist Systems in Residential Dwellings." If you find mildew, mold or water damage on your joists, call a plumber to find and repair any leaks you have before attempting a joist repair. Need aHole Reinforcer instead? In addition, the carbon fiber grid is easily milled and recycled, making it reusable and highly sustainable. Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. Choosing a selection results in a full page refresh. Nolan Engineering, PLLC. Screws work better, but need to be in tightly dimensioned holes.Even 16d nails are a little small for the compressive strength of most wood types in this type of application. 10.02. Any load on the gable roof above, i.e. Add to basket. 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Same day shipping on orders placed Mon-Fri before 3pm, The DP24 will repair a notch up to 6" wide. The moment of inertia of the three 2 x 10 southern yellow pine joists used for a test section was calculated to be 296.8 inches^4. Items that are suspended from TJI joists may rub against the joist flange, resulting in a squeak. Choosing a selection results in a full page refresh. We Recommend Home Hacks & Answers SKU: HWSIJX07. Skyline Joist Reinforcer solutions are strongest and Reinforcers made for routing plumbing, wiring, and HVAC right through floor joists. In this free webinar series we dive into some very important considerations including the latest industry standards, material properties and key governing limits when designing with FRP. x 5 in. This- however- doesn't mean that bridging is a superior floor reinforcement method to floor joist blocking; as the latter method also has its upsides. Please download the engineering report for additional details. Working in teams of two, each carpenter begins by laying out an end of the room at 16 inches on-center. Please download the engineering report for aditional details. That wasn't evident in the results. We use cookies on this site to enhance your user experience. Model # RPS28Z. If your project requires faster service please call and we will do our best toaccommodate your needs. The DP34 Deep Notch Repair Kit restores the strength of Floor Joists resulting from very deep notch cuts from the bottom of the Joist up. Not only did the aggressive notching doom this joist, it affected the structural integrity of the floor system above. We showed them to the plumbers; they had never seen them before, and were very interested. The joists are true 2x8 or thereabouts. Shop products from small business brands sold in Amazons store. Deeply cut floor joists which leave only a small section of wood for support are a difficult problem to solve. What if the flange of a TJI Joist is loose from the web? This is where the wood comes in. The moment of inertia of the three 2 x 10 southern yellow pine joists used for a test section was calculated to be 296.8 inches^4. 2.56. Assuming the joists are in good condition, the solution to both sagging and bounciness problems is to reinforce the floor. be fixed on the side, top or bottom, as appropriate to the joist type. Steel strapping is a way to stiffen an already installed joist.A test to failure is not meaningful here. That for the steel reinforced joists was calculated to be 512.5 inches^4. Thankfully the existing rim joist was an 8x8 beam. 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Same day shipping on orders placed Mon-Fri before 3pm. Repairs Bowing Foundation Walls. Alternately, you can just tense the element directly with a cinch, come-along, or turnbuckle. All fasteners and driver tip are included. Clamp the two boards together and drill holes through both for long 1/2-inch bolts. [4] I saw a report once that showed good results using powder actuated tools to drive nails through the flitch and clinched over.Like any other use of powder actuated tools getting sufficient impact force to drive, without over-driving, the fastener is an issue. 2x10 HR Floor Joist Hole Repair Kit for reinforcing joist or truss holes, route utilities right through floor joists 155 reviews $64.95 $59.95 Sale 2x10 DNR Deep Notch Floor Joist Reinforcer - For deep notch cuts up to edge of joist, truss, in structural member 23 reviews $99.99 $79.95 Sale Notch can be up to 6" wide. Thank you for your help". Burnt Hills, NY 12027 The Simpson Strong-Tie CI family of crack repair products has a solution for almost every job. Landscape Architects & Landscape Designers, Outdoor Lighting & Audio/Visual Specialists, Need help with awkward laundry room/bathroom floor plan. PrivacyPolicy. Descriptions: The 2810HR Joist Reinforcer allows the placement of a 6" diameter hole in a 210 or 212 wood joist and a 4" diameter hole in a 28. Critical Deck-Framing Connections, Part 2: Beams and Support Posts. Manufactured from galvanized steel or strong steel, joist straps secure the two sides of timber beams. The DP24 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. Provides Attic Access With Limited Damage to Rafters. The DP34 works for notches up to 16" wide. You need to transfer a portion of the load to the steel and fixizin describes a good way to do it. 1-16 of 710 results for "Joist Straps" RESULTS 6 Pcs Connector Straps, Steel 14-Gauge Hurricane Tie ,Hot Dip Galvanized Joist Hangers Fit 4 X Truss to Rafter Connector , for Roofing Trusses Wood Timber Connectors 4 $1999 FREE delivery Thu, Feb 16 on $25 of items shipped by Amazon Or fastest delivery Tue, Feb 14 ATTENTION INTERNATIONAL CUSTOMERS: CUSTOMS FEE MAY BE INCURRED UPON DELIVERY. for pricing and availability. Notch size is 6" wide and 5.25" deep, allowing for the custom installation of plumbing, electrical, or other utilities. Basement Wall Strap. Please contact us directly if you have any concerns if this product is the correct solution for you.**. Common Repairs. Sabrefix Heavy Duty Restraint Straps 10 Pack (74769) (19) 69.99 Inc Vat Click & Collect Delivery compare Sabrefix Heavy Duty Angle Brackets Galvanised 60 x 50mm 10 Pack (61576) (158) Can be secured with nails, screws or bolts 9.99 Inc Vat Click & Collect Delivery compare Sabrefix Builders Band Galvanised DX275 9.6m x 20mm (38619) (66) Was 10.99 In the thread on this forum "Reinforceing floor " started by "Galroc,", http://ths.gardenweb.com/forums/load/repair/msg0915531723856.html. Skyline Joist Reinforcer solutions are strongest and Reinforcers made for routing plumbing, wiring, and HVAC right through floor joists. Copyright 2022 Simpson Strong-Tie Company, Inc. Repair, Protection and Strengthening Systems for Concrete and Masonry, Soft-Story Retrofits for Building Resiliency, Repair, Protection & Strengthening Systems, Unreinforced Masonry (URM) Building Retrofit, Cross-Laminated Timber (CLT) & Mass Timber Connector Products, Anchoring Solutions for Value-Added Manufacturing, Component Manufacturers Software Solutions, Component Manufacturer Software Solutions, Federal Procurement & Domestic Content Programs, Outdoor Living: Where Great Backyards Begin, New Product Testing in a Virtual Environment, Simpson Strong-Tie Materials Demonstration Laboratory at Cal Poly, Simpson Strong-Tie Research and Testing Laboratory at WSU, Repair and Protection Systems for Concrete and Masonry, Contact Webmaster with questions or comments. 4. The better approach would be to install steel on the SIDES of the joist, oriented vertically. Reduce where other loads govern. Adding steel at the BOTTOM of the joist THEORETICALLY increases the area moment, ONLY if the steel is jointed intimately to the wood, thereby putting x-section of the steel in pure tension. The DP30 will repair a notch up to 16" wide. Watch on Purchase Download Joist Strap Design Report (PDF) 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, 2x10 HR Floor Joist Hole Repair Kit for reinforcing joist or truss holes, route utilities right through floor joists, 2x10 DNR Deep Notch Floor Joist Reinforcer - For deep notch cuts up to edge of joist, truss, in structural member, 2x8 DNR Deep Notch Floor Joist Notch Repair Kit - For cuts to edge of joist, truss, or structural members, i-Joist Web Reinforcer Repair Kit - 1.5in, 2.5in, 3.5in flange width 9.5in, 11.875in, 14in, and 16in height, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device. Sioux Chief 524-1022PK2 3/4-Inch by 10-Feet 22-Gauge Metal Hanger Strap, TEJATAN - Straight Steel Brace (Also Known as - Straight Bracket, Straight Metal Bracket, Steel Straight Brace, Steel Straight Brackets) (Set of 10), Oatey 33923 28 Ga. Galvanized Hanger Strap, Bagged - 3/4-Inch x 10-Feet, 6 Pcs Tie Plate Bracket Flat Length 8", Carbon Steel Width 3" Metal Joint Thickness 2mm Flat Mending Repair Plate Corner Brace Heavy Duty Strap for Trusses Wood Timber, Light Gauge Steel Framing, Simpson Strong Tie LU28-25PK - 2X8 20 Gauge Face Mount Joist Hangers - Quantity 25, Simpson Strong-tie H2.5A-25PK - 18-Gauge Galvanized Hurricane Tie 25ct (25pk), 10 PCS Flat Tee Mending Plate, T Flat Repair Tie Plate, Strong T Strap Steel Right Angle Bracket, Thickness 2mm, Metal Corner Brace for Wood, Furniture, Timber Connector(Silver), 4Pcs Steel 14-Gauge Hurricane Tie , Heavy Duty Hot Dip Galvanized Joist Hangers Fit 4X Truss to Rafter Connector , Thickness 2 mm for Roofing Trusses Wood Timber Connectors, vikofan 4PCS Joist Hangers,4x6" Black Joist Hanger Fit for Beam/Swing, Cord strapping rolls for heavy packages securing, Emergency Medical Backboard Spine Board Straps. To repair floor joists, the damaged joist is sistered together with a new piece of wood. At times when this isn't possible, shorter pieces are used instead (this is sometimes referred to as scabbing). Notches at the end of the joist should be no deeper than 1/4 the depth. Those joists are so cut up that there's really nothing left of them. Minimum holes size still needs to be used with multiple smaller fasteners being less likely to exceed the compressive limit of the wood under load transfer. Our Joist Strap is a safe way to repair the joist, created by structural engineers who know all about load-bearing requirements. snow, pushes down on the roof. The strap is wide enough to increase the contact area and provide improved nail spacing to enhance the performance of . That's pretty ingenious and SIMPLE with the wedges even better if the strap can be anchored not on the bottom, but "around the corner" on the ends. Click Hereto open chart to determine what size strap is needed. A small amount of sag in joists under a load is normal . When the entire room is laid out, we snap chalk lines on the ceiling to ensure a straight and clean installation. Asphalt Pavement Reinforcement Solutions Now you can build roads that are stronger and more economical. Simpson Strong-Tie has become a trusted manufacturer of chemical, mechanical, direct-fastening, and carbide drill bits and accessories since entering the market in 1994. x 4 in. Sorry to bring my engineering curiosity to the tail end of this discussion, but wouldn't ANY scheme of cladding (for lack of better term) steel onto existing wood joists have to include FIRST UNloading (i.e. The key is the steel will not help if the load is already being carried by the wood. Ideally, the projector's projection (sorry) into the ceiling space should be boxed closely, meaning only cut out enough of the joist for the 30" required for the projector plus the two headers, and add the cut section of the joist back between the headers (in front of or behind the PJ, so the 48" becomes 34") to provide better floor support. Improved rigidity can also be achieved by securely bolting a gusset made of ply to a nearby truss or rafter and to a ceiling joist below. An easier way of doing this is to forget the jacking and attach a steel strap only at the beam ends and then drive a opposed wedges between the steel and the joist at mid span. Outside Diameter), CS 25 ft. 16-Gauge Galvanized Coiled Strap, HTT 16 in. Call us at 540-589-9669. The unique rolled edges of the strap allow it to span gaps as wide as 4 1/2", and its 1 1/2" width enables installation on the narrow face of 2x lumber. For three-part installations, install two parts on one side, one part on opposite side. 4. Replacing some part with a piece fastened on, such as a steel strap on the bottom, is really making it into a composite joist. Many of these products are approved for installation with Strong-Drive SD Connector screws. Works with as little as 2" of wood remaining at the top of the Joist. The plywood should run parallel to the joists, not across them. That for the steel reinforced joists was calculated to be 512.5 inches^4. In-progress photo of the pier and beam repairs along the stem wall. This method has been used for flitch beams to increase load rating also. There is an engineered design report available by using the link above that can be provided to a Building Department, if required. CONTACT US FOR MORE INFORMATION. Ties masonry to masonry for structural (load bearing) & non-structural intersecting CMU walls. im curious to hear brickeyee's response to this comment!!!!!!! Have an exterminator solve the insect problem before fixing your joists. Repair detail for TJI joists with holes too close to bearing. Here is a link that might be useful: Here is a more complete discussion. Restraint straps should be provided along the direction of the joists and spaced at a maximum of 2m centres. Like you said, I handed him the Intertech Report. Skyline Joist Reinforcer solutions are strongest and Reinforcers made for routing plumbing, wiring, and HVAC right through floor joists. Replacing a TJIJoist. Notches are only allowed in the first 1/3 from each end of the Joist.2. Even though I seemed to be the only one who noticed it, I just couldn't stand the wobble. Two connections per deck are all that's needed. Do you have any miracle products that can get me get one more inch of stairway head clearance? Standard (IBC) Size: 16 gauge - 1/2 sq x 6 x 14 Other sizes available - Call 1-800-659-4731 or sales@masonpro.com Finish: Hot Dip Product Data Sheet SDS Hot Dip LEED Purchase Online Intersecting CMU Walls (Flange Action - Shear Transfer): Z-Strap It's not necessary to transfer the entire strength of the steel strap to the wood joist; it only needs to be stiffened enough to reduce deflection and "bounce" to a more comfortable level. We feel much better about the floor after installation of the reinforcers. The DP24 Deep Notch Repair Kit restores the strength of Floor Joists resulting from very deep notch cuts from the bottom of the Joist up. Cast Iron sink in an Ikea cabinetnon apron. FYI: We specify linear foot to distinguish this measurement from square footage. This style of framing is not correct for this type of structure. Fasteners: Nail dimensions in the table are diameter by length. With the exception of weekends, we make every attempt to ship orders within24 hours of when they are received. Insert and tighten a 3/8 bolt. This ensures your floor is secured while the damaged sill is removed and replaced. The steel straps were 1.5-inch by 1/8-inch, and were nailed to the joists with 16p nails 6-inches on center. So, has anyone on this forum tried the steel strap method and observed, even qualitatively, a significant reduction in sag or an apparent significant increase in floor stiffness? Joist Straps. The DP34 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. I was able to achieve my remodel as intended and it's already closed up and finished. When renovating a building, you might be challenged by floor joists that have been cut to allow for pipes or conduits to pass through, or you may be considering cutting existing joists to install new plumbing or conduits. The Design Report is stamped by certified Engineers in multiple States and has been accepted by Building Inspectors across the United States and Canada. Our reinforcement grids are made from carbon fiber or glass fibers. Installation Instructions and Eng Report. You can see it recommended in this article http://www.taunton.com/finehomebuilding/PDF/Free/021184090.pdf, * Posted by fixizin (My Page) onWed, Apr 8, 09 at 18:30, Here is a link that might be useful: Stiffen Floors, "The key is the steel will not help if the load is already being carried by the wood.". These innovative products are the result of more than 40 years of laboratory development, field study and contractor input and have passed the rigorous performance and quality assurance testing you have come to expect from Simpson Strong-Tie. If the fasteners are sized and placed properly the steel strap works quite well. Notches can be placed anywhere along the length of the Joist up to 12" from supporting members.2. Tack a beam under the sagging joists. Joist Repair Kit. Side Note: Being in a High-Velocity Hurricane Zone (HVHZ), and having a roofing system designed to hold concrete tiles which weigh 940-1080 lbs./square(! I wonder what they measure for flitch beams?They will fail with oversize holes also. . Instead of just waiting for these floor joist problems to become unmissable in your home, talk to a JES expert about scheduling a free inspection to help with your problems. Then, apply a construction adhesive along each joist and lift the plywood into position. Well, at least not on the joist holes. Connect strapping to a filler block that has been securely attached to the TJI joist web (Figure 7). However, while the measured moment of inertia for the unreinforced joists was 300.4 inches^4, very close to the calculated value, that for the steel strap reinforced joists was only 324.4 inches^4, a very modest increase for a lot of work. AVAILABLE in US and CANADA -Please include mobile phone and email for tracking via text and email. Then repeat the process to set the other end of the sistered joist to match the old joist. Large gaps at the ceiling joist ends require structural remediation. Scabbing is a simple and affordable yet effective joist reinforcement method. Soft-Story Retrofits for Building Resiliency, Repair, Protection & Strengthening Systems, Unreinforced Masonry (URM) Building Retrofit, Cross-Laminated Timber (CLT) & Mass Timber Connector Products, Anchoring Solutions for Value-Added Manufacturing, Component Manufacturers Software Solutions, Component Manufacturer Software Solutions, Federal Procurement & Domestic Content Programs, Outdoor Living: Where Great Backyards Begin, New Product Testing in a Virtual Environment, Simpson Strong-Tie Materials Demonstration Laboratory at Cal Poly, Simpson Strong-Tie Research and Testing Laboratory at WSU, Wood Construction Connectors Technical and Installation Notes, C-C-2021 (Wood Construction Connectors), page 307, Fastener Types and Sizes Specified for Simpson Strong-Tie Connectors, Contact Webmaster with questions or comments, Tested specifically for top/bottom plate repair with various multi-strap configurations, Meets the requirements of the IBC and IRC for repairing top plates that have been cut or notched to accommodate plumbing or HVAC ductwork. Feel free to call, text, or email 24/7 customer service if you have questions.
Jesse Marsch Daughter,
Articles J